€5,018.60*
Please log in to receive your conditions.
Available, delivery time: 1-2 days
Product number:
100704
GTIN:
4260682383839
Measurement parameters:
water hardness
Measuring range:
0.89 - 448 ppm
Application:
Universal for water treatment plants | TÜV-certified for devices with wide range power supply 100-240 VAC / 100-353 VDC, EN 61010-1:2010 | NRTL-certified UL 61010-1:2012/R:2015-07, CAN/CSA-C22.2 No. 61010-1:2012 + UPD No. 1:2015-07
Menu navigation:
German, English, French, Mandarin (Chinese), Dutch, Portuguese, Polish, Russian, Spanish, Czech, Turkish (other languages on request)
Our comment:
Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100
Would you like to register the warranty for this product?
Register warranty here
A warranty extension is possible after taking out an indicator subscription.
Register warranty here
A warranty extension is possible after taking out an indicator subscription.
Order the appropriate original indicator for your TESTOMAT® device:
Determine the appropriate reagent here: Reagent consumption calculator
Testomat® indicator TH 2005 2x100ml | Order · Subscription |
Testomat® indicator TH 2025 2x100ml | Order · Subscription |
Testomat® indicator TH2050 2x100ml | Order · Subscription |
Testomat® indicator TH 2100 2x100ml | Order · Subscription |
Testomat® indicator TH 2250 2x100ml | Order · Subscription |
Testomat® indicator TH 2005, 500ml | Order · Subscription |
Testomat® indicator TH 2025 500ml | Order · Subscription |
Testomat® indicator TH2050 500ml | Order · Subscription |
Testomat® indicator TH 2100 500ml. | Order · Subscription |
Testomat® indicator TH 2250 500ml. | Order · Subscription |
Offer as PDF
Login for addressed offer The entered number of pieces will be taken into account when creating the offer.
Login for addressed offer The entered number of pieces will be taken into account when creating the offer.
Product information "Testomat® EVO (Successor Testomat® ECO)"
The Testomat® ECO / EVO automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water.
Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified (only version with wide-range power supply unit).
The Testomat® EVO TH is supplied without a power switch. This is done to comply with the DIN EN 61010-1 safety standard for measuring, control and laboratory equipment. Of course, an external mains switch will be made available to you as a customer for purchase. You can order this from us as a disconnector under article no. 850925, "external cam switch with protection class IP65".
The Testomat® style="letter-spacing: 0px;"> EVO TH convinces with new functionalities:
- Optical water detection when filling the measuring chamber
- BOB operation (operation without constant supervision)
- Import and export of settings (basic programming) with selectable file name
- Logging of measurement data and messages / alarms using an integrated SD or optional SDHC card (2GByte)
- Firmware update via SD card
- LCD graphic display
- Multilingual menu with easy switching (internal programming is retained)
- Integrated self-test with continuous monitoring
- External clear / acknowledge input
- Free programmable password
- Automatic bleeding of the indicator line
- Doors can be changed individually
- Range monitoring (fall below limit value1 / exceed limit value 2)
- Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)
- High-precision titration using a piston dosing pump
- Analogue output 0/4 - 20 mA
- Serial RS232 interface for transfer of measurement data and messages/alarms
- Programmable hardness unit in ° dH, ° f, ppm CaCO3, mmol / l
- 2 independent limits with adjustable switching functions as well as switching option in accordance with an adjustable number of negative
- analyzes
- Analysis initiation:
- automatic interval operation (0-99 minutes)
- depending on quantity via contact water meter
- Indicator quantities: 100 und 500 ml bottles
Dimensions
Height | 48 cm |
---|---|
Length | 28 cm |
Width | 38 cm |
Weight
Weight | 9,1 kg |
---|
Other attributes
Country of origin | EU |
---|---|
Customs tariff number | 90278990 |
Technical specifications
Supply voltage: | switching power supply 100-240 VAC, 100-353 VDC |
Power consumption: | max. 30 VA |
Protection class: | I |
Protection: | IP 44 |
Ambient temperature: | 10–40 °C |
Water temperature: | 10–40 °C |
Dimensions (W x H x D): | 380 x 480 x 280 mm |
Operating pressure: | 1 bis 8 bar / 1x105 bis 8x105 Pa Oder 0,3* bis 1 bar / 0,3x105 bis 1x105 Pa (after removal of the valve body) |
Weight: | approx. 9,0 kg |
Menu Language: | German, English, French, Dutch, Spanish, Turkish, Chinese, Czech, Russian (others on request) |
Measuring range: | Water hardness: 0.89 - 448 ppm |