The Neomeris Chlorine Dioxide Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of three different ppm chlorine dioxide measurement ranges for your measurement. The basis here ist the amperometric measurement.Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5 or 0-10ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery:
1 pcs. Chlorine Dioxide 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery:
1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Measuring resistor (temperature sensor):
without
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:without temperature sensorS8 N-srew head Pg13,5, PPS
materialPTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Measuring resistor (temperature sensor):
PT1000
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:PT1000 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Measuring resistor (temperature sensor):
PT100
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:PT100 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/840Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
The Neomeris Chlorine Dioxide Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of three different ppm chlorine dioxide measurement ranges for your measurement. The basis here ist the amperometric measurement.Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5 or 0-10ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery:
1 pcs. Chlorine Dioxide 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery:
1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery:
1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
The Neomeris Chlorine Dioxide Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of three different ppm chlorine dioxide measurement ranges for your measurement. The basis here ist the amperometric measurement.Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5 or 0-10ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery:
1 pcs. Chlorine Dioxide 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
Our Neomeris Free Chlorine Sensors are specifically designed for disinfection applications in water treatment and swimming pools. There is a choice of four different ppm free chlorine measurement ranges. (Determination of free chlorine by amperometric method)Typical further applications are: Industrial waste waterCooling waterBottle rinsingIrrigation water in agricultureand many others.Signal outputThe measured value is easily and reliably transferred to your control or display system by means of a 4-20mA signal with a scaling of 0-2, 0-5, 0-10 or 0-20ppm.MaintenanceThe membrane cap mounted on the sensor, as well as the included electrolyte solution, are easily replaceable by the user. This regular maintenance on the sensor helps to extend the service life in the application and to always obtain an optimal measurement result. MountingThe sensor is mounted in the separately available flow cell and, in addition to this, we offer you the flow meter required for this to ensure stable measurement.Scope of delivery:
1 pcs. Free Chlorine 4-20mA Sensor 2 pcs. replacement cap & brand 2 pcs. 30mL refill solution 3 pcs. cathode polishing squares
- 1 side connected to solenoid valve connector without seal
("Plug and Play", as plug only has to be plugged onto measuring cell)- 1 side labelled cable with wire end ferruleswhite: PT100brown: PT100yellow: Measuring cell
SL green: Measuring cellblue: shielding
- 1 side connected to solenoid valve connector without seal
("Plug and Play", as plug only has to be plugged onto measuring cell)- 1 side labelled cable with wire end ferruleswhite: PT100brown: PT100yellow: Measuring cell
SL green: Measuring cellblue: shielding
Cooler consists of Titanium steel 1.4571 for automatic sampling to 120°C hot water.
Max.water pressure/hot water: 16 bar
Max.water pressure/cold water: 8 bar
Connections:
Cold water inlet: ½
Cold water outlet (canal): ½
Hot water (in- and outlet): 8 mm
Dimensions: 546 x 128 mm
You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for automatic sampling to 200°C hot water.
Max.water pressure/hot water: 16 bar
Max.water pressure/cold water: 8 bar
Connections:
Cold water inlet: ½
Cold water outlet (canal): ½
Hot water (in- and outlet): 8 mm
Dimensions: 546 x 128 mm
You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for automatic sampling to 80°C hot water.
Max.water pressure/hot water: 16 bar
Max.water pressure/cold water: 8 bar
Connections:
Cold water inlet: ½
Cold water outlet (canal): ½
Hot water (in- and outlet): 8 mm
Dimensions: 598 x 335 mm
You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for manual sampling to 120°C hot water.
Max.water pressure/hot water: 16 bar
Max.water pressure/cold water: 8 bar
Connections:
Cold water inlet: ½
Cold water outlet (canal): ½
Hot water (in- and outlet): 8 mm
Dimensions: 598 x 335 mm
You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for for manual sampling to 80°C hot water.
Max.water pressure/hot water: 16 bar
Max.water pressure/cold water: 8 bar
Connections:
Cold water inlet: 8 mm
Cold water outlet: ½
Hot water (in- and outlet): 8 mm
Dimensions: 413 x 335 mm
You can find a detailed description of the cooler in the technical data sheet for download on this page.