Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Measuring resistor (temperature sensor):
without
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:without temperature sensorS8 N-srew head Pg13,5, PPS
materialPTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Measuring resistor (temperature sensor):
PT1000
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:PT1000 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Measuring resistor (temperature sensor):
PT100
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:PT100 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/840Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Connection cable for pH/redox
Length: 3 metres
Cable type: pH and redox connection cable Ø 5 mm, 75 °C
Connection end 1 (sensor side): rotatable cable socket
Connection end 2 (device side): without
Electronic sensors for analysing liquids require special connection cables and plug connectors.
The following applies in principle:
The connection between an electrochemical sensor and the transmitter/indicator/controller should be as short as possible. Normally, the cable length is 5 to 10 metres to ensure a high level of functional reliability. If longer cable lengths are required in exceptional cases, the technical documentation for the sensors and measuring devices should be consulted. The cable between the sensor and the analyser must be laid directly, without interruptions such as terminal strips or cable extensions.
pH and redox measurement
Special coaxial cables with a special design are used for pH and redox measurement. During these measurements, the sensor generates low-intensity DC voltages which are transmitted to the analyser. Due to the sometimes very high internal resistance (potentiostatic measuring principle with internal resistances of up to several gigaohms), these measurements are extremely sensitive to electrical interference and the effects of radiation. Under unfavourable conditions, even minimal movements of the cable can lead to measurement value distortions. An additional insulation layer of the JUMO coaxial cable increases the insulation resistance, which enables a secure connection of the sensor to the transmitter. Conventional coaxial cables from the antenna and computer sector are not suitable for this application and can damage the sensors. This can lead to immediate failure of the sensor as well as a shortened service life. For multiple sensors, for example with integrated temperature sensors, coaxial cables with single wires are available, such as the Variopin (VP).
Active part:
HA glass: pH 0 ... 14; -5 ... +80°C (high alkali use)
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
Ring-gap diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeFeatures: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water Use our configurator created for you and configure yourself the suitable electrode. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet.
Active part:
HT-Glas: pH 0 ... 14; -5 ... +135°C
|
Basic type supplement:
Glass shaft, high-temperature gel, sealed, cartridge discharge system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
120mm
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Active part:
HT-Glas: pH 0 ... 14; -5 ... +135°C
|
Basic type supplement:
Glass shaft, high-temperature gel, sealed, cartridge discharge system
|
Diaphragm:
Hole diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salt reserve + with integrated Pt100
|
Insertion length:
120mm
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
Hole diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salt reserve + with integrated Pt100
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
Hole diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Temperature sensor Pt100
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salt reserve + with integrated Pt100
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
PEI plastic shaft with protective cage, glass fibre diaphragm, cartridge discharge system
|
Diaphragm:
1x glass silk
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt storage + double chamber (DOKA) with KCL/KCL bridge
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Plastic shaft PSU with protective basket, glass silk diaphragm, cartridge discharge system
|
Diaphragm:
1x glass silk
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
225mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Plastic shaft PSU without protection cage, glass silk diaphragm, cartridge discharge system
|
Diaphragm:
1x glass silk
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
225mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
HT-Glas: pH 0 ... 14; 0 ... +110°C
|
Diaphragm:
Ring-gap diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: Screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-12-10-22/837
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Diaphragm:
Ring-gap diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salzreserve + mit integriertem Pt1000
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Extra codes: Salt reserve, with integrated Pt1000Order code: 201020/79-12-10-18/837, 841
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Diaphragm:
Ring-gap diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-18-10-22/837
Active part:
HT-Glas: pH 0 ... 14; 0 ... +110°C
|
Diaphragm:
Ring-gap diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salzreserve + mit integriertem Pt1000
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Type supplements: Salt reserve, with integrated Pt1000Order code: 201020/79-18-10/837, 841