Product information "JUMO AQUIS 500 CR - conductivity, TDS, resistivity, temperature transmitter/controller in surface mount housing, 1x 0(4)-20mA / 0(2)to 10V output + 1x relay output, AC 110 to 240V power supply"
- Direct switching option to specific
- Automatic temperature compensation: off (e.g. USP), linear, ASTM, natural waters (EN 27888/ISO 7888)
- Large LC graphic display with backlighting
- Display presentation selectable: large digits, bargraph or tendency display
- Calibration options depending on measured variable: cell constant and temperature coefficient
- Calibration logbook
- Connection possibility of two-electrode measuring cells (standard) or four-electrode measuring cells
- Activatable contamination detection
- Autorange operation
- Protection class IP67 for surface mounting Protection class IP65 for control cabinet mounting
- Operator languages switchable: German, English, French; other languages via setup program Rechargeable
- Through setup program: convenient programming, system documentation, Loading of further operator languages
Dimensions
Height | 14 cm |
---|---|
Length | 34,5 cm |
Width | 22,5 cm |
Weight
Weight | 1,3 kg |
---|
Other attributes
Country of origin | DE |
---|---|
Customs tariff number | 90278930 |
Downloads:
JUMO AQUIS 500 CR |
Basic type |
Output 1 |
Output 2 |
Output 3 |
Output 4 |
Power supply |
Extra codes |
surface-mounted housing |
analogue, 0(4) to 20 mA resp. 0(2) to 10V |
analogue, 0(4) to 20 mA resp. 0(2) to 10V |
Relay with switch contact |
Relay with switch contact |
AC 110 to 240 V |
||
Variant 1 |
• |
• |
• |
• |
• |
• |
none |
Variant 2 |
• |
• |
no Output |
• |
no Output |
• |
none |
individual |
according to type sheet, please inform us of your request |
Technical Inputs |
||||||||||
Main input |
Indicating range |
Accuracy |
Temperature impact |
|||||||
µS/cm |
0.000 to 9.999 00.00 to 99.99 000.0 to 999.9 0000 to 9999 |
£ 0,6 % v. MB + 0,3 µS x Cell constant (K) |
0,2 %/10 K |
|||||||
mS/cm |
0.000 to 9.999 00.00 to 99.99 000.0 to 999.9 0000 to 9999 |
£ 0,6 % v. MB + 0,3 µS x Cell constant (K) |
0,2 %/10 K |
|||||||
kW x cm |
0.000 to 9.999 00.00 to 99.99 000.0 to 999.9 0000 to 9999 |
£ 0,6 % v. MB + 0,3 µS x Cell constant (K) |
0,2 %/10 K |
|||||||
kW x cm |
0.000 to 9.999 00.00 to 99.99 000.0 to 999.9 0000 to 9999 |
£ 0,6 % v. MB + 0,3 µS x Cell constant (K) |
0,2 %/10 K |
|||||||
Nebeneingang |
Measuring range |
Accuracy |
Temperature impact |
|||||||
Temperature Pt100/1000 (automatic detection) |
-50 to +250 °Ca |
£ 0,5 °C |
0,05 %/10 K |
|||||||
Temperature NTC/PTC |
max. 4 kW Input by table with 20 value pairs via setup programme |
£ 0,3 %b |
0,05 %/10 K |
|||||||
a Switchable in °F. b Depending on the supporting points. |
||||||||||
Temperaturecompensation |
||||||||||
Type of compensation |
Rangea |
|||||||||
Linear 0 to 8 %/K |
-10 to 160 °C |
|||||||||
ASTM D1125 – 95 (Ultrapure water) |
0 to 100 °C |
|||||||||
Natural waters (ISO 7888) |
0 to 36 °C |
|||||||||
Referencetemperature |
||||||||||
Adjustable 15 to 30 °C; preset to 25 °C (standard) |
||||||||||
a Observe the operating temperature range of the sensor! |
||||||||||
Measuring circuit monitoring |
||||||||||
Inputs |
Underrange/ Overrange |
Short-circuit |
Wire break |
|||||||
Conductivity |
yes |
depending on the measuring range |
depending on the measuring range |
|||||||
Temperature |
yes |
yes |
yes |
|||||||
Dual-electrode system |
||||||||||
Cell constant (1/cm) |
Setting range of the relative cell constant |
resulting usable area (1/cm) |
||||||||
0.01 |
20 to 500 % |
0.002 to 0.05 |
||||||||
0.1 |
0.02 to 0.5 |
|||||||||
1.0 |
0.2 to 5 |
|||||||||
3.0 |
0.6 to 15 |
|||||||||
10.0 |
2.0 to 50 |
|||||||||
Vier-Elektroden-Systeme |
||||||||||
Cell constant (1/cm) |
Setting range of the relative cell constant |
resulting usable area (1/cm) |
||||||||
0.5 |
20 to 150 % |
0.1 to 0.75 |
||||||||
1.0 |
0.2 to 1.5 |
|||||||||
Binary Input |
||||||||||
Activation |
through potential-free contact |
|||||||||
Function |
Key lock HOLD Alarm suppression |
|||||||||
Controller |
||||||||||
Controller type |
Limit comparators, limit controllers, pulse width controllers, pulse frequency controllers, three-point stepping controllers, continuous controllers |
|||||||||
Controller structure |
P/PI/PD/PID |
|||||||||
A/D converter |
Dynamic resolution up to 14 bit |
|||||||||
Sampling time |
500 ms |
|||||||||
Analogue Outputs (max. 2) |
||||||||||
Output type |
Signal range |
Accuracy |
Temperature impact |
permissible load resistance |
||||||
Power signal |
0/4 to 20 mA |
£ 0.25 % |
0.08 %/10 K |
£ 500 W |
||||||
Voltage signal |
0 to 10 V |
£ 0.25 % |
0.08 %/10 K |
£ 500 W |
||||||
The analogue outputs behave according to the recommendation of NAMUR NE43. They are galvanically isolated, AC 30 V / DC 50 V. |
||||||||||
Switching outputs (maximum two changeover contacts) |
||||||||||
Nominal load |
AC 3 A/250 V (resistive load) |
|||||||||
Contact lifetime |
>2 × 105 Switching at nominal load |
|||||||||
Setup-Interface |
||||||||||
Interface for configuring the unit with the optimally available setup programme (used exclusively for configuring the unit). |
||||||||||
Electrical data |
||||||||||
Voltage supply |
AC 110 to 240 V; -15/+10 %; 48 to 63 Hz AC/DC 20 to 30 V; 48 to 63 Hz DC12 to 24 V; +/-15 % (Connection only permitted to SELV/PELV circuits) |
|||||||||
Power consumption |
approx. 14 VA |
|||||||||
Electrical safety |
DIN EN 61 010, Part 1 Overvoltage category IIIa, Pollution level 2 |
|||||||||
Data backup |
EEPROM |
|||||||||
Electrical connection |
Screw terminals Wire cross-section max 2.5 mm 2 (power supply, relay outputs, sensor inputs)2 Wire cross-section max 1.5 mm2 (analogue outputs; ISFET supply) |
|||||||||
a Not valid for protective extra-low voltage of the power supply variant DC 12 to 24 V. |
||||||||||
Display |
||||||||||
Graphic LC display |
120 x 32 pixels |
|||||||||
Backlight |
Programmable: - off - 60 seconds on during operation |
|||||||||
Housing |
||||||||||
Material |
ABS |
|||||||||
Cable feed |
Cable glands, max. 3 × M16 and 2 × M12) |
|||||||||
Feature |
Venting element to prevent dew formation |
|||||||||
Reference temperature range (Accuracy specifications are adhered to in this range) |
-10 to +50°C |
|||||||||
Operating temperature range (Function of the unit is given) |
-15 to +65°C |
|||||||||
Storage temperature range |
-30 to +70°C |
|||||||||
Climate resistance |
rel. Humidity £ 90 % annual average without condensation (based on DIN EN 60721 3-3 3K3) |
|||||||||
Protection classes according EN 60529 |
Surface-mounted housing: IP67 Control cabinet installation: front IP65, rear IP20 |
|||||||||
Swinging |
according DIN EN 60068-2-6 |
|||||||||
Weight |
Surface-mounted housing: approx. 900 g Control cabinet installation: approx. 480 g |
|||||||||
Dimensions |
see data sheet |
|||||||||
Approvals/Mark of Conformity |
||||||||||
Mark of conformity |
Test centre |
Certificates/Test numbers |
Basis for testing |
Applies to |
||||||
c UL us |
Underwriters Laboratories |
E 201387 |
UL 61010-1 |
all versions |